Design of Aeration Systems

Which standards and guideline values must be considered when designing aeration systems?

For the design of aeration systems in municipal wastewater treatment plants, DWA-A 131 is the key guideline for process design of activated sludge systems, while DWA-M 229-1 governs the planning, sizing, arrangement, and energy evaluation of aeration and mixing systems. 

In addition, DIN EN 12255-6 defines fundamental requirements for activated sludge processes, whereas DIN EN 12255-15 standardizes clean-water oxygen transfer testing. 

Practically relevant parameters include oxygen demand, SOTR or αSOTR, alpha factor, airflow rate, submergence depth, pressure loss, control range, and adequate mixing without sedimentation. These parameters must be evaluated for minimum, average, and maximum operating conditions. For oxygen transfer measurement and verification, DWA-M 209 and internationally ASCE/EWRI 2-22 are commonly used. Universal fixed guideline values exist only to a limited extent because design always depends on treatment objectives, basin geometry, wastewater characteristics, and energy-efficiency requirements. 

Sources:

  • Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e. V. (DWA), 2016, DWA-A 131: Bemessung von einstufigen Belebungsanlagen, Hennef/DWA
  • Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e. V. (DWA), 2021, DWA-M 229-1: Systeme zur Belüftung und Durchmischung von Belebungsanlagen – Teil 1: Planung, Ausschreibung und Ausführung, korrigierte Fassung, Hennef/DWA
  • DIN, 2002, DIN EN 12255-6: Kläranlagen – Teil 6: Belebungsverfahren, Berlin/Beuth
  • DIN, 2004, DIN EN 12255-15: Kläranlagen – Teil 15: Messung der Sauerstoffzufuhr in Reinwasser in Belüftungsbecken von Belebungsanlagen, Berlin/Beuth