Industrial Wastewater Treatment with CLEARTEC® Fixed Bed Biofilm Technology
Philippines 2016
Inflow | Outlet | Legal requirement | ||
COD | (mg/L) | 835 | 20 | 100 |
BOD5 | (mg/L) | 267 | 14 | 50 |
TSS | (mg/L) | 300 | 14 | 70 |
Inflow
COD: 835 mg/L
BOD5: 267 mg/L
TSS: 300 mg/L
Outlet
COD: 20 mg/L
BOD5: 14 mg/L
TSS: 14 mg/L
Legal requirement
COD: 100 mg/L
BOD5: 50 mg/
TSS: 70 mg/
India 2019
Tunisia 2022
Inflow | Outlet | Removal rate | ||
COD | (mg/L) | 5000 | 419 | 92 % |
BOD5 | (mg/L) | 2400 | 299 | 88 % |
Inflow
COD: 5000 mg/L
BOD5: 2400 mg/L
Outlet
COD: 419 mg/L
BOD5: 299 mg/L
Removal rate
COD: 92 %
BOD5: 88 %
Tunisia 2022
Inflow | Outlet | Removal rate | ||
COD | (mg/L) | 2940 | 317 | 98 % |
BOD5 | (mg/L) | 1800 | 67 | 96 % |
Inflow
COD: 2940 mg/L
BOD5: 1800 mg/L
Outlet
COD: 317 mg/L
BOD5: 67 mg/L
Removal rate
COD: 98 %
BOD5: 96 %
Tunisia 2022
Inflow | Outlet | Removal rate | ||
COD | (mg/L) | 4000 | 142 | 89 % |
BOD5 | (mg/L) | 1460 | 11 | 96 % |
Inflow
COD: 4000 mg/L
BOD5: 1460 mg/L
Outlet
COD: 142 mg/L
BOD5: 11 mg/L
Removal rate
COD: 89 %
BOD5: 96 %
Jäger Umwelt-Technik GmbH
Lohweg 1
30559 Hannover (Germany)
Tel. +49 511 – 64644 0
Fax +49 511 – 64644 499
info@jaeger-envirotech.com
Managers:
Dr.-Ing. Andreas Jäger,
Hans-Christian von Consbruch
Register Court Hannover HRB 212566
DE300467016