Logo Jäger Umwelt-Technik

Municipal

Reference sewage treatment plant Geiselbullach, Olchingen

The system was planned and commissioned as a conventional system, but has been optimized and adapted to ShearCon over the years.
Geiselbullach Klaeranlage
Type of wastewater treatment plantMunicipal
Maximum inflow80.000 m³/d
Output size250,000 PE
Biological stage2-lane design
2 anoxic tanks
2 anaerobic tanks
2 anaerobic tanks
Operating modeUpstream denitrification
Bio-P (additional P precipitation)
Purification targetsNitrification
Denitrification
P-elimination

Type of wastewater treatment plant: Municipal
Maximum inflow: 80.000 m³/d
Output size: 250.000 PE
Biological stage: 2-lane design, 2 anoxic tanks, 2 anaerobic tanks, 2 anaerobic tanks
Operating mode: Upstream denitrification, Bio-P (additional P precipitation)
Purification targets: Nitrification, Denitrification, P-elimination

Why was the plant equipped with a textile fixed bed?

In the late 1980s, the legal requirements for N-elimination became stricter for German wastewater treatment plants. The operators of the Geiselbullach sewage treatment plant therefore decided to convert the existing conventional activated sludge system into an IFAS process and tested various growth carriers. In 1996, after several years of trials, the final decision was made in favor of Cleartec® BioCurlz and it was installed in both aeration tanks. For more than 17 years, the IFAS system provided the required effluent quality. But over time, the ceramic diffusers broke. For these reasons, the operator decided to replace the entire system, but to continue using Cleartec® technology. The installation began in spring 2013 and was approved a few months later. Since then, the system has been running stably and continues to safely comply with all discharge values.
Schlingen nach 3 Tagen
Curlz after 3 days
Schlingen nach 2 Wochen
Curlz after 2 weeks
Schlingen nach 2 Monaten
Curlz after 2 months

1987 (without CLEARTEC®)

ParametersInlet [mg/l]Outflow [mg/l]Removal rate [%]
CSB3215382,9
BSB51721193,5
NH4-N363211,1

Inlet

CSB: 321 mg/l
BSB4: 172 mg/l
NH4-N: 36 mg/l

Outflow

CSB: 53 mg/l
BSB4: 11 mg/l
NH4-N: 32 mg/l

Removal rate

CSB: 82,9 %
BSB4: 93,5 %
NH4-N: 11,1 %

2022 (with CLEARTEC®)

ParametersInlet [mg/l]Outflow [mg/l]Removal rate [%]Limit value [mg/l]
CSB6021996,833
BSB52131,399,415
NH4-N401,17 (Jan-Dez)97,1-
NH4-N400,3 (Mai-Okt)99,310

Inlet

CSB: 602 mg/l
BSB4: 213 mg/l
NH4-N: 40 mg/l

Outflow

CSB: 19 mg/l
BSB4: 1,3 mg/l
NH4-N: 1,17 mg/l (Jan-Dez)
NH4-N: 0,3 mg/l (Mai-Okt)

Removal rate

CSB: 96,8 %
BSB4: 99,4 %
NH4-N: 97,1 % (Jan-Dez)
NH4-N: 99,3 % (Mai-Okt)

Limit value

CSB: 33 mg/l
BSB4: 15 mg/l
NH4-N: 10 mg/l 

Kontakt JUT

Linker Bereich

Please select a sales area.

José Igual

Sales j.igual@jaeger-envirotech.com

Sales Natcha Kosolkamolmas

Natcha Kosolkamolmas

Sales

Tel. +49 51164644415 n.kosolkamolmas@jaeger-envirotech.com

Jaeger Rubber & Plastics (Shenzhen) Ltd.

Tel. +86 755 - 29832412 info@jaeger-shenzhen.cn

Rechter Bereich

Write us a message!

Checkboxen *

* = mandatory field

Please select a valid form